ROTH TerraStar Heat Pumps V-Series
WATER-TO-AIR
Two-Stage, R-410a
Packaged Vertical
Unit Specication Catalog
P/N 2300100903
...Your environment is our business...
Call 888-266-7684 US or 800-969-7684 CAN or visit our website at www.roth-america.com
Seitenansicht 0
1 2 3 4 5 6 ... 31 32

Inhaltsverzeichnis

Seite 1 - WATER-TO-AIR

ROTH TerraStar Heat Pumps V-SeriesWATER-TO-AIRTwo-Stage, R-410aPackaged VerticalUnit Specication CatalogP/N 2300100903...Your environment is our busi

Seite 2 - Table of Contents:

EWT Flow Airow HC HE LAT COP DH Airow TC SC HR EER DH°F GPM PSI FT CFM MBtuh MBtuh °F W/W MBtuh CFM MBtuh MBtuh MBtuh Btuh/W MBtuh1500 35.2 25.2 91.

Seite 3

EWT Flow Airow HC HE LAT COP DH Airow TC SC HR EER DH°F GPM PSI FT CFM MBtuh MBtuh °F W/W MBtuh CFM MBtuh MBtuh MBtuh Btuh/W MBtuh1350 30.7 21.2 91.

Seite 4 - Unit Performance:

EWT Flow Airow HC HE LAT COP DH Airow TC SC HR EER DH°F GPM PSI FT CFM MBtuh MBtuh °F W/W MBtuh CFM MBtuh MBtuh MBtuh Btuh/W MBtuh1750 44.1 30.9 93.

Seite 5 - Roth Geothermal Heat Pumps

EWT Flow Airow HC HE LAT COP DH Airow TC SC HR EER DH¡F GPM PSI FT CFM MBtuh MBtuh ¡F W/W MBtuh CFM MBtuh MBtuh MBtuh Btuh/W MBtuh1475 37.8 25.9 93.

Seite 6 - Water Flow Selection

EWT Flow Airow HC HE LAT COP DH Airow TC SC HR EER DH°F GPM PSI FT CFM MBtuh MBtuh °F W/W MBtuh CFM MBtuh MBtuh MBtuh Btuh/W MBtuh1750 52.7 37.4 97.

Seite 7

Heating Correction FactorsCooling Correction Factors Sensible Cooling Correction FactorsEAT °F HC HE kW50 1.0465 1.1188 0.802455 1.0351 1.0918 0.84366

Seite 8

Dual Capacity Vertical Model Number 024 036 048 060 072Fan Wheel (in.)Future Models10 x 11 10 x

Seite 9

Notes:All Desuperheater connections are 3/4” FPT.All measurements are in inches.ModelDimensional Datawithout Control BoxDimensional Datawith Control B

Seite 10

ModelVoltageCode60Hz Power CompressorECMFan MotorFLAHWGPumpFLAExt Loop PumpFLA*Total UnitFLAMinCircuitAMPSMax Fuse HACRMin AWGMaxFtVolts Phase LRA RLA

Seite 11

TECHNICAL DATA (AHTR Electric Heaters only) Single Phase w/ Circuit BreakerHeater ModelSupply VoltageHeat kWSupply Circuit NumberHeater kW Per Circuit

Seite 12

1RXT Series Catalog - August 2010 RothTable of Contents:Product Introduction & Unit Features ...

Seite 13

MICROPROCESSOR FEATURES AND OPERATION Roth’s geothermal heat pump controls provide a unique modular approach for controlling heat pump operation. The

Seite 14

Loop Pump Circuit Breakers (Single Compressor Units)The loop pump(s) and desuperheater pump are protected by control box mounted circuit breakers for

Seite 15 - Correction Factors

Intelligent Reset If the thermostat is powered off and back on (soft reset), the board will reset, but the last fault will be stored in memory for eas

Seite 16 - Physical Data

the over/under voltage feature is disabled. On rare occasions, variations in voltage will be outside the range of the over/under voltage feature, whi

Seite 17 - Vertical Upow Conguration

Cooling, 2nd Stage (Y1,Y2,O,G) Two-Stage Units The ECM fan adjusts to 2nd stage CFM level, and the compressor full load solenoid valve is energized.Co

Seite 18 - Electrical Data

ECM Fan Performance - Two-Stage Compressor UnitsModel1Program2Heating Modes Cooling ModesDehumidication Mode6OnlyFanDIP Switch Settings41st Stage2nd

Seite 19 - Electrical Data:

25RXT Series Catalog - August 2010 RothControls

Seite 20 - Controls

26Roth RXT Series Catalog - August 2010Engineering SpecicationsGeneralThe Geothermal Heat Pump system and the earth loop shall be one system and incl

Seite 21

27RXT Series Catalog - August 2010 RothOptions, Accessories, & WarrantyDesuperheaterOptional desuperheater package of vented double wall copper co

Seite 22

28Roth RXT Series Catalog - August 2010 STANDARD RESIDENTIAL WARRANTY Roth Industries, Inc. for brand: “TerraStar” Resid

Seite 23

2Roth RXT Series Catalog - August 2010Product Introduction & Unit FeaturesRoth is turning the geothermal heat pump industry in a new direction! Ro

Seite 24

29RXT Series Catalog - August 2010 Roth

Seite 25

30Roth RXT Series Catalog - August 2010Revision TableDate: By: Page: Description:August 2010 KT All First Published

Seite 26

Roth Industries, Inc.P.O. Box 245Syracuse, NY 13211888-266-7684 US800-969-7684 CAN866-462-2914 [email protected]* AHRI certica

Seite 27 - Engineering Specications

Ground Loop Heat PumpGround Water Heat PumpNote: Rated in accordance with ISO Standard 13256-1 which includes Pump Penalties.Heating capacities based

Seite 28

CFM = Airow, Cubic Feet/Minute HR = Total Heat Of Rejection, Btu/hrCOP = Coecient of Performance = BTU Output / BTU Input KW = Total Power Unit Inpu

Seite 29

Heating CoolingLAT = EAT + HC CFM x 1.08LAT (DB) = EAT (DB) - SC C

Seite 30

EWT Flow Airow HC HE LAT COP DH Airow TC SC HR EER DH°F GPM PSI FT CFM MBtuh MBtuh °F W/W MBtuh CFM MBtuh MBtuh MBtuh Btuh/W MBtuh850 17.3 12.0 88.8

Seite 31 - Revision Table

EWT Flow Airow HC HE LAT COP DH Airow TC SC HR EER DH°F GPM PSI FT CFM MBtuh MBtuh °F W/W MBtuh CFM MBtuh MBtuh MBtuh Btuh/W MBtuh1050 25.6 18.3 92.

Seite 32 - Roth Industries, Inc

EWT Flow Airow HC HE LAT COP DH Airow TC SC HR EER DH°F GPM PSI FT CFM MBtuh MBtuh °F W/W MBtuh CFM MBtuh MBtuh MBtuh Btuh/W MBtuh1150 23.1 16.0 88.